Page 79 - 4274
P. 79

50 ft long, and pup joints space out as required.
                                   The  top  section  of  the  drilling  riser  system  includes  the
                            upper  163/4-in.  diameter,  5,000-psi  WP  flex  joint,  drilling  riser
                            tensioner, tensioner spool, and BOP stack. The upper flex joint is
                            located  just  below  the  TLP  deck  levels  and  allows  larger  riser
                            angles  than  could  otherwise  be  accommodated  within  the  TLP
                            deck arrangements. Bearing points on the lower structural level of
                            the TLP decks are required to maintain the upper portion of the
                            drilling riser in a vertical position.





























                                         Figure 2.32 – High pressure drilling riser assembly















                                                           79