The parameter 1,3×d n approximately takes into account the structural sizes of the thickness of
            a washer, the height of a nut and stocked on length of a stud. For the implementation of the
            simplified drawing of a stud joint the followings correlations are used: D=2 d n;  D w=2,2 d n;
            H=0,8 d n; S w=0,15  d n.
                  The structural drawing of a stud joint is shown in figure 4.22, and it is simplified in figure
            4.22, b.





































                                            а)                             b)
                                               Figure 4.22 – The stud joint



                  The parameters of a stud jack are found according to the followings dependences:
                                d opening=0,85 d n; L opening=L 1+0,5 d n.
                  According to these parameters a stud jack is done in figure 4.23.






















                                               Figure 4.23 – The stud jack