Page 30 - 5010
P. 30

(Q = V / τ) by means of the stopwatch and the measuring capacity.
                     w
                             w
                  For this purpose determine the volume of water V  which filled the
                                                                                     w
                  measuring  capacity  during  the  time  τ.  (The  stable  water  filtration
                  regime  is  controlled  by  the  repeated  water  flow  rate  measurement).

                  Conduct  the  experiments  5  –  7  times  under  different  pressure
                  differences.
                        4.4.6  Draw the  graph  of  dependence Q = f (ΔР) (for control the

                  linearity of water filtration).
                        Water  filtration  through  the rock sample  must  be  according  to
                  the linear law that is the graph of dependence Q = f (ΔР) must be a
                  straight line.











                                                              to the atmosphere






















                  Lines : I –  filtration lines; II – supply  lines; III – gas lines;  IV – manifolds

                  1, 2  –  measuring presses; 3  – hand-power press; 4  – tanks; 5  –  manometers;

                  6, 12 – filters; 7 – core holder; 8 – differential manometer;  9 – cylinder with

                  pressed gas; 10 – capacity with  a dryer; 11 – tank; 13 – piston container;

                  14 – electric motor; 15 – worm reduction gear; 16 – friction variable-speed

                  drive; 17 – reduction gear of  planet type; 18 – gears.


                  Figure 4.2 – Installation IIPC-1M (УДПК-1М)




                                                              29
   25   26   27   28   29   30   31   32   33   34   35