(Q = V / τ) by means of the stopwatch and the measuring capacity.
w
w
For this purpose determine the volume of water V which filled the
w
measuring capacity during the time τ. (The stable water filtration
regime is controlled by the repeated water flow rate measurement).
Conduct the experiments 5 – 7 times under different pressure
differences.
4.4.6 Draw the graph of dependence Q = f (ΔР) (for control the
linearity of water filtration).
Water filtration through the rock sample must be according to
the linear law that is the graph of dependence Q = f (ΔР) must be a
straight line.
to the atmosphere
Lines : I – filtration lines; II – supply lines; III – gas lines; IV – manifolds
1, 2 – measuring presses; 3 – hand-power press; 4 – tanks; 5 – manometers;
6, 12 – filters; 7 – core holder; 8 – differential manometer; 9 – cylinder with
pressed gas; 10 – capacity with a dryer; 11 – tank; 13 – piston container;
14 – electric motor; 15 – worm reduction gear; 16 – friction variable-speed
drive; 17 – reduction gear of planet type; 18 – gears.
Figure 4.2 – Installation IIPC-1M (УДПК-1М)