modifications, could be defined and corrected. In West Texas
during 1972, the first chemical proportioning pump was used to
force-inject liquid sulfite 0 2 scavenger into the pump suction line
through fittings while drilling. These pumps had found their place
in all of the production and petrochemical areas, but somehow
drilling personnel had failed to use them. It was found that, with
proper use, less chemical was added to achieve desired results. The
fluid in the mud pump suction is the only fluid going downhole, and
it should be at a low corrosion rate to perform downhole. Corrosion
rates were much higher downhole than imagined, compared to
surface rates. Research to define this was performed, and dynamic
closed loop corrosion rate circulators were designed. This research
resulted in an excellent explanation of the drilling systems. When
failures occurred, more accurate work was needed and the
metallurgical labs were used. This proved that working with both
operator and contractor, the problem can be described and
corrected; the key is to monitor and act accordingly.
8 КОРОЗІЯ БУРИЛЬНОЇ ТРУБИ
Огляд розробок систем бурових розчинів за 40 років, які
мають відношення до захисту труб свердловини від корозії,
включаючи опис систем і приклади.
Текст представляє короткий огляд систем промивки
свердловини буровим розчином і відповідні тенденцій корозії
в бурових розчинах, які використовувались від 1940 до
середини –1990-х. У ній роздумують про майбутню техніку
проведення робіт та захисні покриття. Важливі технічні
поняття, що стосуються обговорення тем вказаного періоду
включають:
– ключові поняття систем;
– хімічні характеристики, які впливають на корозію;
120