Page 83 - 6634
P. 83

  Accommodation sprinkler system

                      deluge/foam system to:


                 heli-refuelling tanks

                 process platform

                 swivel on turret

                 manually operated water jets and foam applicators

                      The capacity of the main fire water pump is estimated for the worst event,

               i.e. a cargo fire, requiring simultaneous operation of the following.

                  foam system

                  process deluge system

                  turret deluge system


                  two water jets

               Fuel Oil System

                      A diesel oil system serves the various machinery on the vessel, comprising

               the following main components:

                      Fuel oil storage tanks

                      Piping from the filling station on the main deck to the storage tanks

                      One settling tank with a capacity of approx. 40 m3

                      Two fuel oil transfer pumps (one as standby)

                      One fuel oil purifier

                      One pre-heater

               7.4.6.6 Offloading

                      Cargo  offloading  can  be  arranged  through  several  means,  either  direct

               transfer. i.e. FPSO to shuttle tanker through:

                            Offloading reel

                            Trailing hose

                            Loading buoy

                      or indirectly through a permanently moored attending FSO.