Page 83 - 6634
P. 83
Accommodation sprinkler system
deluge/foam system to:
heli-refuelling tanks
process platform
swivel on turret
manually operated water jets and foam applicators
The capacity of the main fire water pump is estimated for the worst event,
i.e. a cargo fire, requiring simultaneous operation of the following.
foam system
process deluge system
turret deluge system
two water jets
Fuel Oil System
A diesel oil system serves the various machinery on the vessel, comprising
the following main components:
Fuel oil storage tanks
Piping from the filling station on the main deck to the storage tanks
One settling tank with a capacity of approx. 40 m3
Two fuel oil transfer pumps (one as standby)
One fuel oil purifier
One pre-heater
7.4.6.6 Offloading
Cargo offloading can be arranged through several means, either direct
transfer. i.e. FPSO to shuttle tanker through:
Offloading reel
Trailing hose
Loading buoy
or indirectly through a permanently moored attending FSO.
83