Page 7 - 6373
P. 7

- coefficient
                                   - size,
                                   - point record.
                                   The point of record in the potential probe is in the middle
                            between different nominal electrodes:
                                                            AM     L
                                                        *          .                               (1.1)
                                                             2     2
                                  The  point  of  record  in  gradient  probe  is  in  the  middle
                            between the electrodes of the same name:
                                                        AB    MN     l
                                                    *              .                             (1.2)
                                                        2      2    2
                                                                    p
                                  The size of the potential probe L p  - the distance in meters
                            between different nominal electrodes (L), ie,
                                                              p
                                                            L    L .                                  (1.3)
                                                              p

                                                         g
                                   Size gradient probe L p  - the distance between the point of
                            recording and different nominal electrode (A or M), ie:
                                                                   l
                                                           g
                                                          L   L    .                               (1.4)
                                                            p
                                                                   2
                                   The probe coefficient is calculated by the formula:
                                   for unipolar probe:
                                                                  AM   AN
                                                           u
                                                         K  4            ,                     (1.5)
                                                           p
                                                                    MN
                                   for bipolar probe:
                                                                 AM   BM
                                                          b
                                                        K  4            .                      (1.6)
                                                          p
                                                                    AB
                                   The probe coefficient dimension is in meters. The electrical
                            resistance of rocks is given by:
                                                               U
                                                         K     MN  .                               (1.7)
                                                      rr    p
                                                                I
                                                                 AB
                                 The curves forms of imaginary electric resistance method

















                                                            7
   2   3   4   5   6   7   8   9   10   11   12